Related Experiment Video
Updated: Aug 30, 2026

Software-Assisted Quantitative Measurement of Osteoarthritic Subchondral Bone Thickness
Published on: March 18, 2022
Quantification of bone involvement in Gaucher disease: MR imaging bone marrow burden score as an alternative to Dixon
Mario Maas1, Cornelis van Kuijk, Jaap Stoker
1Department of Radiology, Academic Medical Center, Meibergdreef 9, Suite G1-231, 1105 AZ Amsterdam, the Netherlands. m.maas@amc.uva.nl
Purpose:
To develop a semiquantitative magnetic resonance (MR) imaging bone marrow burden (BMB) score with inclusion of both axial and peripheral bone marrow in Gaucher disease as an alternative to MR imaging with the Dixon quantitative chemical shift imaging (QCSI) technique.
Materials And Methods:
Two experienced musculoskeletal radiologists with no experience in evaluating Gaucher disease blindly analyzed MR images of lumbar spines and femora. Interobserver and intraobserver variability were tested. In addition, the BMB score was determined as a parameter to evaluate bone marrow response to enzyme supplementation therapy. Finally, the BMB score was compared with fat fraction measurements obtained with Dixon QCSI. Differences between groups were analyzed by using the nonparametric Mann-Whitney test. A P value of less than.05 was considered to represent significance. Correlation was calculated by using two-tailed nonparametric rank correlation (Spearman rho).
Results:
In 30 patients (mean age, 39.3 years; age range, 12-71 years) the mean fat fraction was 0.20 (range, 0.08-0.40). The BMB score range was 3-13 points. A significant correlation was found between the two observers when using BMB (rho = 0.91, P <.001). The intraobserver variation showed a significant correlation (rho = 0.99, P <.001). There was a significant correlation between BMB and QCSI (rho = -0.78, P <.001). Although BMB was less sensitive than Dixon QCSI, it showed enough sensitivity to allow detection of bone marrow response to enzyme supplementation therapy.
Conclusion:
BMB is a reproducible semiquantitative scoring system that is easy to use. It combines MR imaging of both axial and peripheral bone marrow and shows a significant correlation with QCSI.
More Related Videos
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
08:42Using Multi-fluorinated Bile Acids and In Vivo Magnetic Resonance Imaging to Measure Bile Acid Transport
Published on: November 27, 2016