Related Experiment Video
Updated: Aug 30, 2026

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Echocardiographic assessment of preload conditions does not help at the neonatal intensive care unit
Jaroslav Hruda1, Ellen G M Rothuis, Ruurd M van Elburg
1Department of Pediatrics, Division of Pediatric Cardiology, VU University Medical Center, Amsterdam, The Netherlands.
To determine the value of noninvasive assessment of right ventricular preload in neonates, a prospective unblinded study was performed. Thirty-seven neonates without heart disease (median birth weight 1390 g, range 900 to 4400) were studied at the neonatal intensive care unit, comparing directly measured central venous pressure (CVP) and two-dimensional echocardiographic measurement of the maximum and minimum diameter of the inferior vena cava and calculated vena cava index (VCI). CVP was higher in conventionally ventilated and high-frequency oscillatory ventilated neonates than in those breathing spontaneously ( p < 0.0001). VCI in high-frequency oscillatory ventilated patients was lower (5 +/- 4) than in spontaneously breathing (56 +/- 19) and conventionally ventilated (49 +/- 19) (p = 0.002) neonates. CVP and VCI were inversely correlated in spontaneously breathing (r = -0.631), but not in conventionally and high-frequency oscillatory ventilated patients. VCI does not predict CVP in ventilated premature neonates, the correlation is limited only to spontaneously breathing infants.
To determine the value of noninvasive assessment of right ventricular preload in neonates, a prospective unblinded study was performed. Thirty-seven neonates without heart disease (median birth weight 1390 g, range 900 to 4400) were studied at the neonatal intensive care unit, comparing directly measured central venous pressure (CVP) and two-dimensional echocardiographic measurement of the maximum and minimum diameter of the inferior vena cava and calculated vena cava index (VCI). CVP was higher in conventionally ventilated and high-frequency oscillatory ventilated neonates than in those breathing spontaneously ( p < 0.0001). VCI in high-frequency oscillatory ventilated patients was lower (5 +/- 4) than in spontaneously breathing (56 +/- 19) and conventionally ventilated (49 +/- 19) (p = 0.002) neonates. CVP and VCI were inversely correlated in spontaneously breathing (r = -0.631), but not in conventionally and high-frequency oscillatory ventilated patients. VCI does not predict CVP in ventilated premature neonates, the correlation is limited only to spontaneously breathing infants.