Related Experiment Video
Updated: Aug 30, 2026

A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
Published on: March 24, 2019
[Femoral fissure after cement restrictor implantation]
M Schneider1, C Heisel, S J Breusch
1Stiftung Orthopädische Universitätsklinik Heidelberg.
Abstract:
Cement restrictors are accepted parts of modern cementing technique and reduce the risk of revision. The restrictor should seal the intramedullary cavity to ensure sustained pressurization and optimal cement penetration into cancellous bone. Significant complications after use of a cement restrictor are rarely described. Dislocation and cement leakage are well known problems. We describe the occurrence of a femoral fissure after insertion of a resorbable Gelatine cement restrictor.