Determination of caffeine using oscillating chemical reaction in a CSTR

Jinzhang Gao1, Jie Ren, Wu Yang

  • 1Institute of Chemistry, Northwest Normal University, Lanzhou 730070, China. jzgao@nwnu.edu.cn

Related Concept Videos

Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Supercritical Fluid Chromatography01:18

Supercritical Fluid Chromatography

Supercritical fluid chromatography (SFC) provides a beneficial substitute for gas chromatography (GC) and liquid chromatography (LC) for certain samples because it merges the top attributes of both techniques. SFC allows the separation and analysis of compounds that GC or LC does not easily manage. These compounds are traditionally nonvolatile or thermally unstable, making GC unsuitable and lacking functional groups required for HPLC analysis.
SFC utilizes a supercritical fluid mobile phase,...
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
Fast Reactions01:27

Fast Reactions

Fast reactions occurring in times shorter than the time needed to mix reactants pose a unique challenge for investigation. In a liquid-phase continuous-flow system, reactants A and B are swiftly pushed into the mixing chamber, where mixing occurs within 1 ms. The reaction mixture then flows through an observation tube, and one measures light absorption to determine species concentrations at various points of the tube. This method is most appropriate when relatively large volumes of reactants...