Characterization of G Protein-coupled Receptors by a Fluorescence-based Calcium Mobilization Assay
Published on: July 28, 2014
Evaluation of FLIPR Calcium 3 Assay Kit--a new no-wash fluorescence calcium indicator reagent
Yingxin Zhang1, Dianne Kowal, Angela Kramer
1Neuroscience Discovery Research, Wyeth Research, Princeton, NJ 08543, USA.
Abstract:
We have evaluated the FLIPR Calcium 3 Assay Kit (Calcium 3), a new no-wash fluorescence calcium indicator dye reagent, for the measurement of agonist-stimulated calcium signaling in cells expressing the serotonin 2C (5-HT(2C)), metabotropic glutamate receptor 5 (mGluR5) and the vasopressin 2 (V2) G-protein-coupled receptors. Calcium 3 yielded equivalent (5-HT(2C)) or superior (mGluR5 and V2) sensitivity to FLUO-4 as indexed by the change in fluorescence counts following agonist application. Assay variability, indexed by CV, using Calcium 3 or FLUO-4 was equivalent with 5-HT(2C) receptor responses although CVs were reduced using Calcium 3 in the examples of the mGluR5 and V2 receptors. Receptor pharmacologies based on agonist EC(50) values were identical when either Calcium 3 or FLUO-4 were utilized. Our results validate Calcium 3 as a compelling alternative to FLUO-4 in the choice of fluorescent dye reagent for studying G-protein-coupled receptors, providing the advantage of a homogenous, no-wash assay format.