Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Real-time catheter tracking and adaptive imaging.

Daniel R Elgort1, Eddy Y Wong, Claudia M Hillenbrand

  • 1Department of Radiology, University Hospitals of Cleveland and Case Western Reserve University, Cleveland, Ohio 44106, USA.

Journal of Magnetic Resonance Imaging : JMRI
|October 28, 2003
PubMed
Summary

This study introduces a real-time magnetic resonance (MR) system that automatically adjusts imaging parameters based on catheter speed during interventional procedures. The system demonstrated high accuracy in tracking and parameter adjustment, enhancing procedural efficiency.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Correction: Occupational Prenatal Radiation Exposure and Occupational Safety: Position Paper for Pregnant and breastfeeding Personnel in Interventional Procedures with Ionizing Radiation.

RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin·2026
Same author

CT-based lung ventilation metrics: reference ranges and pulmonary function test correlations in healthy individuals.

European radiology·2026
Same author

Photon-counting CT for dynamic lung perfusion: validation of a low-dose protocol in a porcine lung transplantation model.

European radiology experimental·2026
Same author

Photon-counting CT vs V/Q SPECT for lobar perfusion quantification in chronic thromboembolic pulmonary hypertension.

European radiology·2026
Same author

Cohort profile: the Resilient Minds national study of mental health and cognitive resilience in community dwelling adults aged 18 to 93.

Frontiers in digital health·2026
Same author

Extent of alveolar collapse in expiratory CT as a prognostic marker in idiopathic pulmonary fibrosis.

PloS one·2026

Area of Science:

  • Medical Imaging
  • Interventional Radiology
  • Magnetic Resonance Imaging (MRI)

Background:

  • Interventional procedures often require real-time imaging guidance.
  • Current MRI systems may have limitations in adapting to the dynamic nature of catheter insertion.
  • Optimizing image parameters in real-time is crucial for procedural success and patient safety.

Purpose of the Study:

  • To evaluate a novel real-time MRI system designed for interventional procedures.
  • To assess the system's ability to adjust imaging parameters dynamically based on catheter insertion speed.
  • To determine the performance and accuracy of this adaptive MRI system.

Main Methods:

  • Implementation of a real-time feedback loop using standard 1.5 T MRI hardware and tracking markers on a catheter.

Related Experiment Videos

  • Automatic adjustment of scan plane, field of view, resolution, and other parameters based on calculated catheter speed.
  • Evaluation conducted using phantom models and in vivo porcine experiments.
  • Main Results:

    • The system accurately localized a moving catheter in the abdominal aorta with precision of approximately 2 mm and 1.5 degrees.
    • The system successfully calculated device speed and adjusted specified image parameters 98% of the time.
    • Real-time image acquisition, reconstruction, and display were achieved.

    Conclusions:

    • The developed real-time MRI system effectively adapts imaging parameters to catheter movement.
    • This technology has the potential to enhance interventional procedures by providing intelligent, automated image optimization.
    • The system allows clinicians to focus on patient care by reducing the need for manual parameter adjustments.