Anterior mandibular positioning device for treatment of snoring and obstructive sleep apnoea
Christian Emil Faber1, Luisa Grymer, Tine Hjorth
1Department of Otorhinolaryngology, University Hospital, Aarhus, Denmark. c.e.faber@dadlnet.dk
Abstract:
The aim of this study was to determine the severity of side effects and the influence on snoring and the AHI (apnoea-hypopnoea index = number of apnoeas and hypopnoeas per hour recording) of an anterior mandibular positioning device (AMP device) for treatment of snoring and obstructive sleep apnoea. Questionnaires were mailed to a consecutive series of 30 patients who had started treatment with an AMP device. The mean follow-up interval from receiving an AMP device to answering the questionnaire was 22 months. The perceived degree of sore teeth increased statistically significantly (p < 0.01) as a result of the AMP device treatment, but there was no increase in the degree of facial pain, salivation, or temporomandibular joint pain. The AMP device treatment resulted in a statistically significant reduction (p < 0.01) of the mean AHI and of the mean percentage of the recording time with loud snoring (p < 0.05). Twenty-two patients out of 30 were still using the device at the time of follow-up. In conclusion, AMP device treatment was associated with only mild side effects and resulted in a statistically significant reduction of the AHI and of the percentage of the recording time with loud snoring.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...