Related Experiment Video
Updated: Aug 30, 2026

Fluorescent Lateral Flow Immunoassay Based on Quantum Dots Nanobeads
Published on: June 28, 2024
Light-emitting diode-based indirect fluorescence detection for simultaneous determination of anions and cations in
Shih-Ju Chen1, Min-Jane Chen, Huan-Tsung Chang
1Department of Chemistry, National Taiwan University, Roosevelt Road, Section 4, Taipei 106, Taiwan.
Abstract:
This report presents simultaneous analysis of cations and anions by capillary electrophoresis (CE) in conjunction with indirect fluorescence detection using a blue light-emitting diode (LED), based on the displacement of fluorescein with anionic EDTA-metal complexes and anions. A new focusing system combined with a plastic lens and a 40x objective was developed and used effectively to focus the diverging beam of the LED on the capillary. The optimum compositions for simultaneous analysis of metal ions and anions are the samples prepared in 5 mM borate, pH 9.2, containing 2 mM EDTA and the background electrolytes (BGEs) consisting of 5 mM borate buffer, 5 microM fluorescein, and 1 microM NaCl at pH 9.2. Using this pre-capillary complexation method, the analysis of a sample containing five metal ions and eight anions was accomplished in 8 min, with the relative standard deviation values for the migration times less than 2.0%. The peak heights against the concentrations of the metal ions and anions are linear in 10-1000 and 50-2000 microM, with correlation coefficients better than 0.998, and 0.982, respectively. The limits of detection at a signal-to-noise ratio 3 of up to 14.6 microM for formate and as low as 3.7 microM for Ni2+. The results of the analyses of pond water and a Chinese herbal soup present the advantages of this method, including simplicity, rapidity, reproducibility, and low costs.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
