Related Experiment Video
Updated: Aug 30, 2026

Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Increasing sensitivity and decreasing spot size using an inexpensive, removable hydrophobic coating for
Stacey J Owen1, Felix S Meier, Stephan Brombacher
1Institute for Marine Biosciences, National Research Council, 1411 Oxford Street, Halifax, Nova Scotia B3H 3Z1, Canada.
Abstract:
Spot size reduction and increased detection sensitivity in matrix-assisted laser desorption/ionisation (MALDI) of small molecules are accomplished by using an inexpensive and removable hydrophobic coating for MALDI targets, based on 3M Scotch Gard surface treatment. Several variations in sample preparation were explored, such as surface coating technique, identity of the matrix, solvent composition, and the type of metal support plate used. These were investigated on both uncoated and coated surfaces and their impact on spot size, crystal coverage, and sensitivity is presented here. Additionally, crystallisation behaviour obtained on coated plates is compared with that on uncoated plates using scanning electron microscope analysis. To demonstrate the potential of the new coating technique, erythromycin A and valinomycin are studied to determine the increase in detection sensitivity of coated plates in comparison to uncoated plates, and to reveal the suitability of the plates for application in combined high-performance liquid chromatography/MALDI (HPLC/MALDI), where widely varying solvent compositions and droplet volumes are observed. It is shown that enhancements in detection sensitivities correlate very well with the achieved spot size reduction. The versatility of the coated plates is also exhibited by the ease of removing the surface layer, after which the plates can be rigorously cleaned without worry about damaging the hydrophobic surface, followed by a quick reapplication of new hydrophobic coating material. This makes the non-polar coating superior to more expensive commercial hydrophobic-coated targets, which are much more delicate to clean. Furthermore, cleaning and reapplication eliminate potential carry-over effects and the easy application procedure also makes the fabrication of inexpensive, disposable MALDI targets readily possible.
More Related Videos
07:12An Efficient Sample Preparation Method to Enhance Carbohydrate Ion Signals in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry
Published on: July 29, 2018
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI-TOF) Mass Spectrometry
Published on: June 10, 2018
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-Assisted Laser Desorption Ionization (MALDI)
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview