Related Experiment Video
Updated: Aug 30, 2026

Fentanyl Analog Screening using LC-TIMS-TOF MS/MS
Published on: November 8, 2024
Toxicological screening with formula-based metabolite identification by liquid chromatography/time-of-flight mass
Anna Pelander1, Ilkka Ojanperä, Suvi Laks
1Department of Forensic Medicine, P.O. Box 40, and Department of Analytical Chemistry, P.O. Box 55, FIN-00014, University of Helsinki, Finland. anna.pelander@helsinki.fi
Abstract:
An analytical procedure was evaluated for the comprehensive toxicological screening of drugs, metabolites, and pesticides in 1-mL urine samples by TurboIon spray liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) in the positive ionization mode and continuous mass measurement. The substance database consisted of exact monoisotopic masses for 637 compounds, of which an LC retention time was available for 392. A macroprogram was refined for extracting the data into a legible report, utilizing metabolic patterns and preset identification criteria. These criteria included +/-30 ppm mass tolerance, a +/-0.2-min window for absolute retention time, if available, and a minimum area count of 500. The limit of detection, determined for 90 compounds, was <0.1 mg/L for 73% of the compounds studied and >1.0 mg/L for 6% of the compounds. For method comparisons, 50 successive autopsy urine samples were analyzed by this method, and the results confirmed by gas chromatography/mass spectrometry (GC/MS). Findings for parent drugs were consistent with both methods; in addition, LC/TOFMS regularly revealed apparently correct findings for metabolites not shown by GC/MS. Mean and median mass accuracy by LC/TOFMS was 7.6 and 5.4 ppm, respectively. The procedure proved well-suited for tentative identification without reference substances. The few false positives emphasized the fact that all three parameters, exact mass, retention time, and metabolite pattern, are required for unequivocal identification.
More Related Videos
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry (UPLC-MS)
Published on: March 14, 2013
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Rapid Identification of Pathogens