Electrochemical Point-of-Care Test for Assessing Serum Paracetamol Concentration: Comparison With Traditional Methods
Johanna K Kujala1,2, Terhi J Lohela1,2,3, Niklas Wester4,5,6
1Individualized Drug Therapy Research Program, Faculty of Medicine, University of Helsinki, Helsinki, Finland.
Abstract:
Rapid serum paracetamol (acetaminophen) concentration measurement is essential in suspected intoxication, but centralized laboratory analyses often delay initiation of antidotal therapy. We studied the feasibility of a novel electrochemical single-walled carbon nanotube/Nafion-based point-of-care (POC) method in detecting paracetamol in 99 suspected overdose patient serum samples. POC was compared with the standard photoelectric enzymatic method (PEM) and ultra-high performance liquid chromatography-photodiode array and corona-charged aerosol detector (UHPLC-DAD-CAD). We also analysed for 900 concomitant pharmaceuticals, drugs and chemicals in 197 samples with time-of-flight mass spectrometry to assess interference with paracetamol concentration measurements. Paracetamol concentrations measured with UHPLC-DAD-CAD ranged between 0 and 2100 μmol/L, with 19% above the therapeutic level (≥ 200 μmol/L). Comparing POC with UHPLC-DAD-CAD, the false positives and negatives were 10% and 15%, respectively, at concentrations ≥ 30 μmol/L. All POC method false negatives occurred at concentrations < 45 μmol/L. PEM showed 8% false positives and negatives compared with UHPLC-DAD-CAD. Other substances detected included caffeine (78%), antidepressants (41%), benzodiazepines (34%) and antipsychotics (28%). They did not interfere with POC concentration measurement. The novel POC method is promising for measuring serum paracetamol at relevant concentrations.
More Related Videos
Related Concept Videos
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Drug Concentrations: Measurements
Plasma...
Therapeutic Drug Monitoring: Drug Analysis Methods
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Measurement of Bioavailability: Pharmacodynamic Methods