Related Experiment Video
Updated: Aug 30, 2026

Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
On-line detection of heavy metals and brominated flame retardants in technical polymers with laser-induced breakdown
Michael Stepputat1, Reinhard Noll
1Fraunhofer-Institut für Lasertechnik, Steinbachstrasse 15, D-52074 Aachen, Germany.
Abstract:
The use of laser-induced breakdown spectrometry (LIBS) for the analysis of heavy metals and brominated flame retardants in end-of-life waste electric and electronic equipment (EOL-WEEE) pieces is investigated. Single- and double-pulse plasma excitation as well as the influence of detection parameters is studied to yield a parameter field with improved sensitivity and limits of detection. A LIBS analyzer was set up as an on-line measuring unit to detect heavy metals and brominated flame retardants in moving EOL-WEEE pieces in an automatic sorting line. An autofocusing unit with an adjustment range of 50 mm was incorporated to permit measurements of objects that pass by a LIBS analyzer with their surfaces at various distances from it. Tests with EOL-WEEE monitor housings on the conveyor belt of a pilot sorting system successfully demonstrated the capability of the LIBS analyzer to quantify the concentration of hazardous elements in real waste EOL-WEEE pieces.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II