Half-scan fan-beam computed tomography with improved noise and resolution properties
Related Experiment Video
Updated: Aug 30, 2026

Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
1Department of Radiology, MC2026, 5841 S. Maryland Avenue, The University of Chicago, Chicago, Illinois 60637, USA.
Abstract:
Half-scan strategy can be used for reducing scanning time and radiation dose delivered to the patient in fan-beam computed tomography (CT). In helical CT, the data weighting/interpolation functions are often devised based upon half-scan configurations. The half-scan fan-beam filtered backprojection (FFBP) algorithm is generally used for image reconstruction from half-scan data. It can, however, be susceptible to sample aliasing and data noise for configurations with short focal lengths and/or large fan-angles, leading to nonuniform resolution and noise properties in reconstructed images. Uniform resolution and noise properties are generally desired because they may lead to an increased utility of reconstructed images in estimation and/or detection/classification tasks. In this work, we propose an algorithm for reconstruction of images with uniform noise and resolution properties in half-scan CT. In an attempt to evaluate the image-noise properties, we derive analytic expressions for image variances obtained by use of the half-scan algorithms. We also perform numerical studies to assess quantitatively the resolution and noise properties of the algorithms. The results in these studies confirm that the proposed algorithm yields images with more uniform spatial resolution and with lower and more uniform noise levels than does the half-scan FFBP algorithm. Empirical results obtained in noise studies also verify the validity of the derived expressions for image variances. The proposed algorithm would be particularly useful for image reconstruction from data acquired by use of configurations with short focal lengths and large field of measurement, which may be encountered in compact micro-CT and radiation therapeutic CT applications. The analytic results of the image-noise properties can be used for image-quality assessment in detection/classification tasks by use of model-observers.
More Related Videos
08:46Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
Published on: April 13, 2016
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...