Chemical modifiers in arsenic determination in biological materials by tungsten coil electrothermal atomic absorption spectrometry
Related Experiment Video
Updated: Aug 30, 2026

Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
C G Bruhn1, V N Huerta, J Y Neira
1Departamento de Análisis Instrumental, Facultad de Farmacia, Universidad de Concepción, PO Box 237, Concepción, Chile. cbruhn@udec.cl
Abstract:
Palladium, iridium, and rhodium are evaluated as possible chemical modifiers in the determination of As in digest solutions of biological materials (human hair and clam) by tungsten coil electrothermal atomic absorption spectrophotometry (TCA-AAS). The modifier in solution was applied onto the coil and thermally pre-reduced; the pre-reduction conditions, the amount of modifier, and the thermal program were optimized. Palladium was not satisfactory, whereas Ir and Rh were effective modifiers and rendered better relative sensitivity for As by a factor of 1.4 and 1.9, respectively compared to the case without modifier. Upon optimization of thermal conditions for As in pre-reduced Ir (2.0 microg) and Rh (2.0 microg) modifiers and in the digest solutions of the study matrices, Rh (2.0 microg) was more effective modifier and was selected as such. The mean within-day repeatability was 2.8% in consecutive measurements (25-100 microg L(-1)) (3 cycles, each of n=6) and confirmed good short-term stability of the absorbance measurements. The mean reproducibility was 4.4% (n=20 in a 3-day period) and the detection limit (3 sigmablank/slope) was 29 pg (n=15). The useful coil lifetime in Rh modifier was extended to 300-400 firings. Validation was by determination of As in the certified reference material (CRM) of "Oyster tissue" solution with a percentage relative error (Erel%) of 2% and percentage relative standard deviation (RSD%) of 3% (n=4), and by analytical recovery of As spiked in CRM of human hair [94 +/- 8% (n=4)]. The methodology is simple, fast (sample readout frequency 21 h(-1)), reliable, of low cost, and was applied to the determination of As in hair samples of exposed and unexposed workers.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
06:23Preparation of DMMTAV and DMDTAV Using DMAV for Environmental Applications: Synthesis, Purification, and Confirmation
Published on: March 9, 2018
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...