Delayed (18)F-FDG PET for detection of paraaortic lymph node metastases in cervical cancer patients
Shih-Ya Ma1, Lai-Chu See, Chyong-Huey Lai
1Department of Nuclear Medicine, Chang Gung Memorial Hospital and Chang Gung University, Taoyuan, Taiwan.
Unlabelled:
This prospective study investigated the usefulness of dual-phase (18)F-FDG PET scans (40 min and 3 h) in detecting paraaortic lymph node (PALN) metastasis for cervical cancer.
Methods:
One hundred four consecutive cervical cancer patients (International Federation of Gynecology and Obstetrics staging Ib-IVb, recurrent or persistent tumors) were included. All patients received a whole-body (18)F-FDG PET scan at 40 min and an additional scan from the T11 level to the inguinal region at 3 h after injection of 370 MBq (18)F-FDG. The maximum standardized uptake value (SUV) and retention index (RI [%], obtained by subtracting the normalized SUV value obtained at 40 min from that at 3 h) of the lesions were determined.
Results:
In all, 38 of the 104 patients were confirmed to have PALN metastases. For 31 patients (81.6%) with 13 upper (L1-L2 level) and 30 lower (L3-L4 level) PALNs, these metastases were detected with the 40-min scan. In addition, for 7 patients (18.4%) with 7 lower PALNs, metastases were found with the 3-h scan (RI = 12.6%). Two patients (3.0%) had 2 false-positive lesions initially (40 min) but were classified as benign with the 3-h scan. The sensitivity, specificity, and accuracy of (18)F-FDG PET scans at 40 min were 81.6%, 97.0%, and 91.3%, respectively. These quantities were all 100% when both the 40-min and 3-h scans were taken together. Eight patients (21.1%) had their treatment planning changed. We divided the 38 patients into 2 subgroups. Subgroup A included those with either only upper or only lower PALN metastases, and subgroup B included those with both upper and lower PALN metastases. In subgroup A, the SUV values were greater in the upper than in the lower PALNs in both the 40-min and 3-h images (P = 0.077). In subgroup B, there was no significant difference of SUV values between upper and lower PALNs in the 40-min (P = 0.433) and 3-h (P = 0.937) images.
Conclusion:
Our results showed that an additional 3-h scan is helpful for PALN detection of cervical cancer patients. A delayed image (3 h) is especially useful for lower PALN metastases.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
10:33Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment
Published on: April 25, 2025
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET