Differential Imaging of Biological Structures with Doubly-resonant Coherent Anti-stokes Raman Scattering (CARS)
Published on: October 17, 2010
Crossed two-beam coherent anti-stokes Raman spectroscopy in dispersive media
Michael J Papac1, Jonathan D Posner, Derek Dunn-Rankin
1Department of Mechanical and Aerospace Engineering, University of California, Irvine, California 92697-3975, USA.
Abstract:
Coherent anti-Stokes Raman spectroscopy (CARS) is a nonlinear optical wave mixing process that is used in gas-phase systems to determine the energy distribution of the probed species (usually N2) and, through a fitting procedure, the temperature giving rise to it. CARS signal strengths are maximized when the phase matching condition is met. Because gases are generally non-dispersive, this phase matching condition can be found geometrically as a function of the crossing angles between the CARS beams and their wavelengths. In addition, perfect phase matching in non-dispersive media occurs automatically for collinear beams. To improve spatial resolution, however, intersecting the laser beams is desirable. Being a third-order process, phase matching for CARS in gases typically requires three input laser beams. This paper discusses and demonstrates the issues of phase matching for CARS when the medium is dispersive, and the ability for CARS phase matching to occur with only two crossed laser beams (one pump and one probe). This two-beam X-CARS in dispersive media can be used as an alignment tool for gas-phase CARS and may be relevant as a simpler diagnostic in high-pressure environments. The paper also discusses the effects of non-ideal phase matching in dispersive and non-dispersive media.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
UV–Vis Spectroscopy: Beer–Lambert Law
Atomic Fluorescence Spectroscopy
2D NMR: Homonuclear Correlation Spectroscopy (COSY)