Performance and reliability of splitless microliter gradient pumps in a metabolic stability study using cytochrome
Fabian Kuhn1, Michael Oehme, Michael Schleimer
1Organic Analytical Chemistry, University of Basel, Neuhausstrasse 31, CH-4057 Basel, Switzerland.
Abstract:
The performance of two commercially available capillary LC pumps (MicroPro (Eldex, USA), Evolution 200 (ProLab, Switzerland)) generating really splitless gradients in the microliter per minute range was tested in detail concerning their applicability for routine drug discovery. A standard method to study metabolic stability against CYP450 isoform 3A4 was selected. This method was transformed into a fast splitless capillary LC-MS method. Both pumps generated reproducible gradients at flows of 5-10 microl/min within 10-15 min. Although gradient formation of the MicroPro system was very reproducible, its equilibration time was too long for fast gradients around 5 microl/min. The Evolution 200 pump offered a good performance with 180 microm i.d. columns at a flow rate of 6 microl/min. The precision of the retention time of the internal standard (ISTD) varied between 1.4 and 3.4% (n = 131-152, three different columns tested). Up to 800 injections of sufficient performance on one column and a stable enough response of the ISTD for 16 h sequence duration were obtained. Accuracy between 95 and 105% and precision < or = 8.4% for 1'-hydroxylated midozolam were reached. The IC50 values of the miniaturized assay (drug candidate BAL4815 1.7 +/- 0.5, itraconazole 0.46 +/- 0.06, and ketoconazole 0.12 +/- 0.01 microM) agreed well with those of the conventional approach. Details concerning method optimization and limitations in operation are discussed in detail. Still, the overall performance of the capillary LC pumps cannot cope completely with that of conventional HPLC pumps in terms of user-friendliness.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
08:06Absolute Quantification of Cell-Free Protein Synthesis Metabolism by Reversed-Phase Liquid Chromatography-Mass Spectrometry
Published on: October 25, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...