Related Experiment Video
Updated: Jul 27, 2026

The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Decontamination of Bacillus thuringiensis spores on selected surfaces by chlorine dioxide gas
Y Han1, Bruce Applegate, R H Linton
1Department of Food Science, 745 Agriculture Mall Dr., West Lafayette, IN 47907-2009, USA.
Abstract:
This work examined the efficacy of chlorine dioxide (ClO2) gas for the decontamination of Bacillus thuringiensis spores on paper, wood, epoxy, and plastic surfaces. Spores representing an inoculation level of approximately 6 log colony-forming units (CFU) per surface were treated with 5, 10, 15, 20, 25, or 30 milligrams per liter (mg/L) ClO2 gas for 12 hours under 85-92 percent relative humidity and at 22 +/- 1 degrees C. Under the tested treatment conditions, the highest population of surviving spores was found on the paper surface and the lowest was found on the plastic surface (p < .05). The 5 mg/L ClO2 gas treatment inactivated 2.5, 3.6, 4.0, and 4.9 log spores per surface on paper, wood, epoxy, and plastic surfaces, respectively. A greater than 5-log reduction of spores was achieved on each surface after the 15 mg/L ClO2 gas treatment. The minimum ClO2 gas concentration needed to completely inactivate the inoculated spores was 30 mg/L for paper and wood surfaces, 25 mg/L for epoxy surfaces, and 20 mg/L for plastic surfaces. The results of this study may provide insight into the parameters of effective decontamination procedures for Bacillus spores.
More Related Videos
07:07Controlled-release of Chlorine Dioxide in a Perforated Packaging System to Extend the Storage Life and Improve the Safety of Grape Tomatoes
Published on: April 7, 2017
10:03Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy
Published on: November 30, 2017
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Chemical Agents for Microbial Control
Microbial Bioremediation of Pesticides
Production of Biopesticides