Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Innovations in high-pressure liquid injection technique for gas chromatography: pressurized liquid injection system
Jim Luong1, Ronda Gras, Richard Tymko
1Dow Chemical Canada, P.O. Bag 16, Highway 15, Fort Saskatchewan, Alberta, Canada, T8L 2P4.
Abstract:
In gas chromatography (GC), highly volatile liquefied hydrocarbons are commonly injected using devices such as high-pressure syringes, piston valves, liquid rotary sampling valves, or vaporizing regulators. Although these techniques are adequate in some cases, there are known deficiencies. A new generation of sampling valve has been recently innovated and commercialized. Some of the highlights of the pressurized liquid injection system (PLIS) include compact size, the capability to directly couple to an injection port without the need for preinjection vaporization and transfer lines, and sample sizes ranging from 0.2 to 2.0 micro L. Although the valve has a specification of helium leak-free rating of 82.7 bar (1200 psig), the valve passes a hydrostatic pressure test of up to 414 bar (6000 psig). In the unheated version of PLIS, vaporization of solutes occur mainly because of the sheering effect of carrier gas in combination with thermal energy drawn from an injection port or a heated adaptor. This was found to be adequate for solutes with high to medium volatility of up to nC14 hydrocarbon. A higher molecular weight range of up to nC44 hydrocarbon can be achieved with the implementation of a heated version of PLIS, in which the channel of the shaft can be resistively heated at a rate of up to 400 degrees C/s. With its first introduction in May 2002, PLIS has gained acceptance amongst practitioners in GC because it addresses a key unarticulated need in sample introduction/enrichment and by specifically targeting many deficiencies encountered in contemporary high-pressure injection devices. In this paper, the design and performance of the various valve systems of PLIS, as well as industrial chromatographic applications, is presented.
More Related Videos
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.