Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Post-column reaction with a 3D-printed two-stage microreactor and flame ionization detection for carbon compound
Jim Luong1, Yujuan Hua2, Ronda Gras1
1Dow Chemical Canada ULC, Highway 15, Fort Saskatchewan, Alberta T8L 2P4, Canada; Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, Private Bag 75 Hobart 7001 Australia.
Abstract:
Fast gas chromatography that leverages the high chromatographic efficiency of narrow bore capillary column technology and temperature programming was successfully integrated with a third-generation low void-volume, 3D-printed two-stage microreactor. Effective management of extra-column effect and the capability to perform post-column backflushing were achieved with the incorporation of a recently commercialized, electronically controlled pneumatic switching device and a deactivated metal three-way microdevice. With this configuration, narrow bore capillary columns having internal diameters between 0.10 and 0.15 mm can be employed to produce chromatographic peaks in the domain of fast gas chromatography, with peak widths at half-height ranging from 0.42 s to 0.92 s for probe compounds having k over a range from 1.7 for toluene to 60 with the last analyte (nC44) eluted in less than 12 min. The carbon independent response capability of the 3D-printed microreactor affords unique and advantaged differentiators, for instance, conducting measurement of the target analytes using one single carbon-containing compound for calibration with an acceptable accuracy of ±10%, achieving a higher degree of accuracy by eliminating the need for multi-level and multi-compound calibration, and improving sensitivity for compounds that are not efficiently ionized by flame ionization detection. Using this platform, repeatability of retention times for 14 probe compounds was less than 0.1% RSD (n = 10), and less than 1.0% RSD (n = 10) for area counts. The utility of the analytical approach was illustrated with relevant, challenging applications.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Ionization Energy
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Principles Of Column Chromatography
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...