Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Characterization and quantitative analysis with GC/TOFMS comparing enhanced separation with tandem-column stop-flow
Tincuta Veriotti1, Richard Sacks
1Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, USA.
Abstract:
Time-of-flight mass spectrometry is unique in that ion abundance ratios are constant over the chromatographic peak profile provided that the peak contains only one component. This provides the means for the automated finding and spectral deconvolution of overlapping chromatographic peaks from completely unknown mixtures if the mass spectra for the overlapping components are sufficiently unique. This can greatly reduce the chromatographic resolution requirements, which allows for very rapid quantitative analysis as well as for high-speed mixture characterization. High-speed GC with stop-flow operation of a series-coupled column ensemble can be used to completely separate some component pairs that coelute from the column ensemble, thus eliminating the need for spectral deconvolution of those mixture components. This provides two options for high-speed qualitative and quantitative analysis, using either the mass spectra from deconvoluted overlapping peaks or the mass spectra from the completely separated peaks obtained with stop-flow operation of the tandem column ensemble. These options are compared with respect to the similarity for spectral matching with a library and to peak area linearity with concentration, calibration plot correlation coefficients, and shot-to-shot reproducibility.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry: Overview
Mass Spectrometers