Related Experiment Video
Updated: Aug 30, 2026

Physiology Lab Demonstration: Glomerular Filtration Rate in a Rat
Published on: July 26, 2015
Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and
Nils Hackstein1, Jan Heckrodt, Wigbert S Rau
1Department of Diagnostic Radiology, Justus-Liebig Universität Giessen, Giessen, Germany. nils.hackstein@radiol.med.uni-giessen.de
Purpose:
To determine the accuracy of single-kidney glomerular filtration rate (GFR) determination using contrast-enhanced dynamic magnetic resonance imaging (MRI) and the Rutland-Patlak plot technique.
Materials And Methods:
Twenty-eight adult patients were included. As reference method, the GFR was measured by plasma clearance using a small bolus injection of iopromide. A three-dimensional gradient-echo (GRE) sequence with a flip angle of 50 degrees was used for MRI; this showed a good linear relationship between gadolinium (Gd)-DTPA concentration and signal change when measured up to a Gd-DTPA concentration of 10 mmol/liter. A slab containing both kidneys and the abdominal aorta was measured 30 times in approximately 3.5 minutes. During this measurement, 15 mL of Gd-DTPA, 0.5 mol/liter diluted to a volume of 60 mL, was injected over 60 seconds. A Rutland-Patlak plot was calculated from the signal changes in the aorta and the renal parenchyma. Single-kidney GFR was calculated for different time windows from the Rutland-Patlak plot slope.
Results:
The best correlation compared to the reference method was found with the GFR calculated from the slope of the Rutland-Patlak plot 40-110 seconds postaortic rise. Pearson's correlation coefficient was r = 0.86, SD was 14.8 mL/minute. In many of the patients, a decrease of the renal signal was observed in the excretory phase, which was probably caused by very high Gd-DTPA concentrations in the collecting tubules.
Conclusion:
Single-kidney GFR can be calculated from dynamic contrast-enhanced MRI. We found a promising correlation of global GFR calculated by MRI compared to the reference method. In any future study, the amount of Gd-DTPA should by reduced to avoid artificial signal drop in the excretory phase induced by the T2* effect.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles.
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...

