Related Experiment Video
Updated: Aug 30, 2026

Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
Standardized test mixture for the characterization of comprehensive two-dimensional gas chromatography columns: the
Jean-Marie D Dimandja1, Garrick C Clouden, Ivelisse Colón
1Department of Chemistry, Spelman College, 350 Spelman Lane, SW Box 279 Atlanta, GA 30314, USA. jdimandja@spelman.edu
Abstract:
A novel column characterization test mixture is developed for use in comprehensive two-dimensional gas chromatography (GC x GC). This mixture has been named the "Phillips mix" in honor of the late professor John B. Phillips, the father of GC x GC. The mixture comprises a series of homologous compounds from structural groups that cover a volatility and polarity range that is similar to the Grob mix, and includes saturated hydrocarbons (alkanes), unsaturated hydrocarbons (alkenes and alkynes), carbonyls (ketones and aldehydes), primary alcohols, fatty acid methyl esters, alkyl ethers, carboxylic acids, aromatics, as well as other unique functional groups (such as amines, etc.). Similarly to the Grob mix in conventional one-dimensional GC, the Phillips mix can be used as a standardized test for performance characterization of GC x GC column sets. Unlike the Grob mix, however, the Phillips mix's most important use is as a practical guideline for column users. This paper addresses some qualitative aspects of the use of the Phillips mix through an investigation of the chromatographic fingerprints of two different GC x GC column combinations.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...