Related Experiment Video
Updated: Aug 29, 2026

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
The effect of different types of flowable restorative resins on microleakage of Class V cavities
A Rüya Yazici1, Gül Ozgünaltay, Berrin Dayangaç
1Hacettepe University, Faculty of Dentistry, Department of Conservative Dentistry, Ankara, Turkey. ruyay@hacettepe.edu.tr
Abstract:
This study evaluated the microleakage of Class V cavities restored with three different types of flowable resin restorative material and compared the effects of using their respective manufacturer's dentin adhesive or a different brand. Class V cavities with the occlusal margin in enamel and the gingival margin in dentin were prepared on the buccal and lingual surfaces of 48 non-carious human molars. The teeth were randomly assigned to three equal groups of 16. The first eight teeth in each group were restored with one of the flowable restorative materials (Filtek Flow, Dyract Flow, Admira Flow) using the manufacturer's recommended dentin adhesive (Single Bond, Prime & Bond NT, Admira Bond), and the remaining eight molars were restored using a different brand of dentin adhesive (Gluma Comfort Bond). The samples were thermocycled 200 times (5 degrees C-55 degrees C) with a one-minute dwell time. They were then immersed in a 2% basic fuchsin solution for 24 hours, sectioned and analyzed by stereomicroscopy. There was no statistically significant difference at the occlusal margins for either restoration used with its respective dentin adhesive. At the gingival margins, there was a significant difference among all groups. Flowable ormocer (Admira Flow/Admira Bond) displayed the least leakage at the gingival margins. When these flowable restoratives were used with a different brand of dentin adhesive, statistically significant differences were observed both on enamel and dentin. None of the restoratives tested fully prevented leakage at the gingival margins. No significant differences in microleakage were observed among the restorative materials used with respect to the manufacturer's dentin adhesive or a different brand except for Admira Flow restorative at the gingival margins. The gingival margins had significantly more microleakage than the occlusal margins (p < 0.05) except in the Admira Flow group, where microleakage at the occlusal and gingival margins was almost equal.
Related Concept Videos
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...