Related Experiment Video
Updated: Aug 4, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Acetabular revision in total hip replacement with a press-fit cup
This study evaluated the use of press-fit cups without screws in 171 hips with contained or small segmental defects during acetabular revisions. Over an average follow-up of 7.4 years, no press-fit cups required revision for aseptic loosening. Three hips showed signs of osteolysis. Cranial and medial migration up to 6 mm occurred in 26% of cases at two years, but no further migration was observed after that. The results suggest that screwless techniques can provide stable, medium-term outcomes in well-selected patients. The authors propose that press-fit cups may be a viable option for acetabular revisions without additional fixation.
Area of Science:
- Orthopedic surgery techniques
- Hip arthroplasty outcomes research
Background:
The role of supplementary screw fixation in acetabular revisions remains uncertain. Prior research has shown mixed outcomes with and without screws. Some studies suggest screws may improve stability in complex cases. Others argue that press-fit cups alone can suffice in select patients. This uncertainty has driven further investigation into alternative fixation strategies. Surgeons seek reliable methods to avoid additional hardware. The long-term success of screwless techniques is not fully established. This gap motivated the current study to evaluate outcomes without screws.
Purpose Of The Study:
This study aimed to assess the effectiveness of press-fit cups without screws in acetabular revisions. The focus was on hips with contained or small segmental defects. The researchers wanted to determine if screwless techniques could achieve stable results. They also sought to evaluate the risk of migration and osteolysis over time. Medium-term clinical and radiological outcomes were the primary goals. The study aimed to provide evidence for well-selected patient groups. It addressed the need for alternatives to traditional screw fixation. The motivation stemmed from the ongoing debate in orthopedic practice.
Main Methods:
The study involved 439 acetabular revisions performed over an eight-year period. A subset of 171 hips with specific defect types was selected. The Morscher press-fit cup was implanted in these cases. No supplementary screws were used for additional fixation. Patients were followed prospectively for clinical and radiological outcomes. A total of 123 hips had a mean follow-up of 7.4 years. Radiological assessments were conducted at regular intervals. The study focused on migration patterns and signs of osteolysis.
Main Results:
Of the 123 hips reviewed, no press-fit cups required revision for aseptic loosening. Three hips showed radiological evidence of osteolysis. Cranial and medial migration up to 6 mm occurred in 44 hips (26%) at two years. No further migration was observed beyond the second post-operative year. The overall clinical outcomes were considered excellent. The results suggest stability without additional fixation. Migration stabilized after the initial two-year period. These findings support the use of press-fit cups in selected cases.
Conclusions:
The authors suggest that acetabular revision without screws is feasible in well-selected patients. The study supports the use of press-fit cups in hips with contained defects. No revision for aseptic loosening was reported during the follow-up period. The migration observed was limited to the first two years. The results indicate that screwless techniques may be effective. The authors propose that press-fit cups can provide stable outcomes. They emphasize the importance of patient selection. These findings contribute to the ongoing debate in orthopedic surgery.
Frequently Asked Questions
The study found no revisions for aseptic loosening and limited migration in 26% of cases.
The study included 171 hips with contained or small segmental defects.
The follow-up revealed no further migration after the first two years, showing long-term stability.
Radiological assessment identified osteolysis in three hips and migration patterns.
The mean follow-up was 7.4 years, ranging from 5 to 10.5 years.
The authors propose that screwless press-fit cups may be effective in well-selected patients.

