Use of control sample for estimation of prediction error in multivariate determination of lidocaine solutions with

Kent Wiberg1, Mattias Andersson, Anders Hagman

  • 1AstraZeneca R&D Södertälje, Pharmaceutical and Analytical R&D, Analytical Development, SE-151 85 Södertälje, Sweden.

Related Concept Videos

Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...