Related Experiment Videos
Aortic dissection after aortic valve replacement--a case report and literature review
Andrea Picchi1, Marta Focardi, Gianni Capannini
1Istituto di Clinica Medica, Università degli Studi di Siena, Italy.
Angiology
|December 12, 2003
Abstract:
Type A aortic dissection occurs in 0.6% of patients late after aortic valve replacement. However, little information is available about risk factors for developing this complication, nor are recommendations for elective replacement of the ascending aorta available. The authors present a 78-year-old woman who developed type A aortic dissection thirty months after aortic valve replacement; ascending aorta was normal at the time of aortic valve replacement.