Related Experiment Video
Updated: Jul 1, 2026

Measurement of Outgassing Rates of Steels
Published on: December 13, 2016
Correlation between quantitative fit factors and workplace protection factors measured in actual workplace
Ziqing Zhuang1, Christopher C Coffey, Paul A Jensen
1National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health (NIOSH), 626 Cochrans Mill Road, Pittsburgh, PA 15236, USA.
Abstract:
Past studies have found little or no correlation between workplace protection factors (WPFs) and quantitative fit factors (FFs). This study investigated the effect of good- and poor-fitting half-facepiece, air-purifying respirators on protection in actual workplace environments at a steel foundry and the correlation between WPFs and FFs. Fifteen burners and welders, who wore respirators voluntarily, and chippers participated in this study. Each subject was fit-tested with two respirator models each with three sizes, for a total of six fit-tests. Models and sizes were assigned this way to provide a wide range of FFs among study participants. Each worker donned the respirator twice per day (at the beginning of the shift and following the lunch break) for 2 days. Quantitative FFs were first obtained for each donning using the PortaCount Plus trade mark in a separate room. Without redonning the respirators, workers performed normal work for 1 to 2 hours, and WPFs were measured by collecting ambient and in-facepiece samples simultaneously. A second fit-test was conducted without disturbing the respirator. FFs were obtained by averaging the results from the first and second fit-tests. The resulting FFs had a geometric mean (GM) of 400 (range=10-6010) and a geometric standard deviation (GSD) of 6.1. Of the 55 valid donnings, 43 were good fitting (FFs> or =100) and 12 were poor fitting (FFs<100). The WPFs had a GM of 920 (range=13-230,000) and a GSD of 17.8. The WPFs were found to be significantly correlated with the FFs (R(2)=.55 and p-value=.0001). Therefore, FF was shown to be a meaningful indicator of respirator performance in actual workplace environments.
Related Concept Videos
Personal Protective Equipment
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a decrease in the...
Design Consideration
The factor of safety is another key aspect...
Factors Affecting Workability
Steel Manufacturing
During this smelting process, limestone plays a crucial role by forming slag. Slag captures impurities within the molten iron, such...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...

