Porcine Cardiac Arrest Model Using an Implantable Defibrillator
Published on: January 9, 2026
Increase in ventricular tachycardia frequency after biventricular implantable cardioverter defibrillator upgrade
Jose M Guerra1, Jianyi Wu, John M Miller
1Cardiovascular Division, Department of Medicine, Krannert Institute of Cardiology, Indiana University School of Medicine, 1800 N. Capitol Avenue, Indianapolis, IN 46202, USA.
Abstract:
We report the case of a patient in whom transvenous left ventricular pacing lead placement at the time of a biventricular upgrade led to an exacerbation of clinical monomorphic ventricular tachycardia (MVT). At implant, slow left ventricular pacing repeatedly induced sustained MVT. However, testing of the biventricular pacing showed no MVT inducibility, and the system was implanted. The patient was readmitted due to multiple episodes of the MVT observed at implant. The MVT was controlled with pharmacotherapy, allowing the patient to continue with biventricular pacing.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Increased pulse rate
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...
Dysrhythmias VI: Management of Dysrhythmias
Cardiomyopathy V: Interprofessional Care