Background:
Drug-refractory ventricular tachycardia (VT) after failed radiofrequency (RF) ablation remains a clinical challenge. Pulsed-field ablation (PFA) is expanding to ventricular applications, but United States experience with focal pulsed-field-only catheters in VT is sparse, and pulsed-field platforms are not equivalent across manufacturers. Here we describe the first United States experience of FARAPOINT focal PFA in patients with refractory VT.
Methods And Results:
We retrospectively reviewed ten consecutive patients who underwent VT ablation with the FARAPOINT (Boston Scientific) focal PFA catheter at a single VA Health Care System between July 2025 and May 2026. All patients had drug-refractory sustained monomorphic VT. Median age was 77 years with a mix of ischemic and nonischemic cardiomyopathy. Six of ten had at least one prior failed catheter ablation. Acute non-inducibility was achieved in all nine patients who underwent formal post-ablation stimulation testing. No procedural complications occurred. Over a median follow-up of 95.5 days, sustained VT recurred in four of ten patients. No patient underwent repeat ablation, required mechanical circulatory support, or died.
Conclusions:
In this initial United States experience, FARAPOINT was safe and acutely effective in patients with ischemic cardiomyopathy within a high-risk cohort with refractory VT and prior failed ablations, including challenging substrates. Prospective multicenter studies are warranted to expand these observations.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiopulmonary Resuscitation III: AED Use