Intracanal distribution patterns of sealers after lateral condensation

S Ryan Facer1, Richard E Walton

  • 1Department of Endodontics, University of Iowa College of Dentistry, Iowa City 52242-1001, USA.

Journal of Endodontics
|December 23, 2003
PubMed

Related Concept Videos

Masonry Cavity Walls01:26

Masonry Cavity Walls

Cavity walls feature a hollow space between the outer and inner wythes, connected only by corrosion-resistant metal ties. When water seeps through the outer wythe, it descends within this cavity, intercepted by flashing and eventually exiting through weep holes. To enhance moisture resistance, the inner wythe's cavity side often receives damp-proofing, doubling as an air barrier. The cavity can also house insulation to mitigate heat transfer.
Maintaining a clean cavity during construction is...
Cavity Drainage and Flashings in Masonry walls01:20

Cavity Drainage and Flashings in Masonry walls

Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Expansion and Contraction in Masonry Walls01:19

Expansion and Contraction in Masonry Walls

Masonry walls are subject to slight expansion and contraction due to variations in temperature and moisture. Thermal movement in masonry is relatively straightforward to measure and plan for. On the other hand, moisture movement poses more of a challenge. New clay masonry units typically absorb water and expand over time under normal environmental conditions. Conversely, new concrete masonry units tend to shrink as they lose the excess moisture acquired during their production process.
To...
Mortar Joint Deterioration in Masonry01:13

Mortar Joint Deterioration in Masonry

Mortar joint deterioration is a significant concern in masonry structures, with water accumulation in the joints leading to damage from freeze-thaw cycles. The repeated expansion of water during freezing and its melting during thawing develop and propagate cracks in the masonry joints. Eventually, this leads to the spalling of mortar from the joints, loosening masonry units and weakening the structure. The deteriorated mortar joints are also vulnerable to moisture intrusion into the walls.
The...