Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
Non-invasive assessment of distribution volume ratios and binding potential: tissue heterogeneity and
M Reimold1, W Mueller-Schauenburg, G A Becker
1Department of Nuclear Medicine, University of Tübingen, Otfried-Müller-Strasse 14, 72076 Tübingen, Germany. matthias.reimold@uni-tuebingen.de
Abstract:
Due to the stochastic nature of radioactive decay, any measurement of radioactivity concentration requires spatial averaging. In pharmacokinetic analysis of time-activity curves (TAC), such averaging over heterogeneous tissues may introduce a systematic error (heterogeneity error) but may also improve the accuracy and precision of parameter estimation. In addition to spatial averaging (inevitable due to limited scanner resolution and intended in ROI analysis), interindividual averaging may theoretically be beneficial, too. The aim of this study was to investigate the effect of such averaging on the binding potential ( BP) calculated with Logan's non-invasive graphical analysis and the "simplified reference tissue method" (SRTM) proposed by Lammertsma and Hume, on the basis of simulated and measured positron emission tomography data [[(11)C] d- threo-methylphenidate (dMP) and [(11)C]raclopride (RAC) PET]. dMP was not quantified with SRTM since the low k(2) (washout rate constant from the first tissue compartment) introduced a high noise sensitivity. Even for considerably different shapes of TAC (dMP PET in parkinsonian patients and healthy controls, [(11)C]raclopride in patients with and without haloperidol medication) and a high variance in the rate constants (e.g. simulated standard deviation of K(1)=25%), the BP obtained from average TAC was close to the mean BP (error <5%). However, unfavourably distributed parameters, especially a correlated large variance in two or more parameters, may lead to larger errors. In Monte Carlo simulations, interindividual averaging before quantification reduced the variance from the SRTM (beyond a critical signal to noise ratio) and the bias in Logan's method. Interindividual averaging may further increase accuracy when there is an error term in the reference tissue assumption E= DV(2)- DV' ( DV(2) = distribution volume of the first tissue compartment, DV' = distribution volume of the reference tissue). This can be explained by the fact that the distribution volume ratio ( DVR= DV/DV') obtained from averaged TAC is an approximation for Sigma DV/Sigma DV' rather than for Sigma DVR/ n. We conclude that Logan's non-invasive method and SRTM are suitable for heterogeneous tissues and that discussion of group differences in PET studies generally should include qualitative and quantitative assessment of interindividually averaged TAC.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
08:13Evaluations of Oxygenation and Vascular Perfusion in Pre-Clinical Models of Cancer and Wound Healing Using OS-DCE OAI
Published on: April 7, 2026
Related Concept Videos
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's overall...
Magnetic Resonance Imaging