Image quality issues in a static image-based telepathology consultation practice
Related Experiment Video
Updated: Aug 29, 2026

Introduction of an Integrated Pathology Image Management, Artificial Intelligence, and Reporting System
Published on: July 11, 2025
Bruce H Williams1, In Soon Hong, Florabel G Mullick
1Department of Telepathology, Armed Forces Institute of Pathology, Washington, DC 20306-6000, USA.
Abstract:
Field selection and image quality have often been identified as impediments in the successful employment of static-image telepathology. One thousand seven hundred fifty-three electronic consultations using static images were performed at the Department of Telemedicine, Armed Forces Institute of Pathology (AFIP) between November 1994 and September 2001, with 98.3% receiving a telepathology diagnosis. In 47.9% of cases, imagery was considered good by AFIP consultants, 38.5% were considered adequate, and 14.6% of cases were considered to have poor-quality imagery. Deficiencies in image quality were recorded for each case. Cases with imagery rated as good averaged significantly fewer deficiencies per case (0.45, range: 0 to 3) than cases with imagery rated adequate (0.95, range: 0 to 6) or poor (2.4, range: 0 to 7). Deficiencies in focus were most commonly identified in this series of cases (28.1%), followed by improper white balancing of the capture device (14.1%) and inadequate resolution (10%). Cases in which images were of inadequate resolution showed an increased likelihood for discordance between the telepathology diagnosis and the diagnosis rendered on follow-up material ("truth diagnosis"). Inadequate field selection, although only cited in 6.7% of cases overall, was seen with a significantly higher frequency in cases in which there was discordance between the telepathology and truth diagnosis. A review of common image deficiencies in static-image telepathology and possible causes is presented.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Three-Dimensional Microscopy in Microbiology