Related Experiment Video
Updated: Aug 29, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Mechanical versus manual ventilation via a face mask during the induction of anesthesia: a prospective, randomized,
Achim von Goedecke1, Wolfgang G Voelckel, Volker Wenzel
1*Department of Anesthesiology and Critical Care Medicine, Leopold-Franzens-University, Innsbruck, Austria; and †Department of Anesthesiology and Intensive Care Medicine, University Hospital of Kiel, Kiel, Germany.
Unlabelled:
One approach to make ventilation safer in an unprotected airway has been to limit tidal volumes; another one might be to limit peak airway pressure, although it is unknown whether adequate tidal volumes can be delivered. Accordingly, the purpose of this study was to evaluate the quality of automatic pressure-controlled ventilation versus manual circle system face-mask ventilation regarding ventilatory variables in an unprotected airway. We studied 41 adults (ASA status I-II) in a prospective, randomized, crossover design with both devices during the induction of anesthesia. Respiratory variables were measured with a pulmonary monitor (CP-100). Pressure-controlled mask ventilation versus circle system ventilation resulted in lower (mean +/- SD) peak airway pressures (10.6 +/- 1.5 cm H(2)O versus 14.4 +/- 2.4 cm H(2)O; P < 0.001), delta airway pressures (8.5 +/- 1.5 cm H(2)O versus 11.9 +/- 2.3 cm H(2)O; P < 0.001), expiratory tidal volume (650 +/- 100 mL versus 680 +/- 100 mL; P = 0.001), minute ventilation (10.4 +/- 1.8 L/min versus 11.6 +/- 1.8 L/min; P < 0.001), and peak inspiratory flow rates (0.81 +/- 0.06 L/s versus 1.06 +/- 0.26 L/s; P < 0.001) but higher inspiratory time fraction (48% +/- 0.8% versus 33% +/- 7.7%; P < 0.001) and end-tidal carbon dioxide (34 +/- 3 mm Hg versus 33 +/- 4 mm Hg; not significant). We conclude that in this model of apneic patients with an unprotected airway, pressure-controlled ventilation resulted in reduced inspiratory peak flow rates and peak airway pressures when compared with circle system ventilation, thus providing an additional patient safety effect during mask ventilation.
Implications:
In this model of apneic patients with an unprotected airway, pressure-controlled ventilation resulted in reduced inspiratory peak flow rates and lower peak airway pressures when compared with circle system ventilation, thus providing an additional patient safety effect during face-mask ventilation.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: