Related Experiment Video
Updated: Aug 29, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Marginal and flexural integrity of three classes of luting cement, with early finishing and water storage
1Department of Biomaterials, Graduate School of Medicine and Dentistry, Okayama University, 2-5-1 Shikata-cho, Okayama 700-8525, Japan. mirie@md.okayama-u.ac.jp
Objectives:
The aims of this investigation were to clarify the effects of finishing-time and 24 h water-storage on mechanical properties and marginal adaptation to dentin of seven modern luting cements, representing three chemical types.
Methods:
Bistite II, Chemiace II, Compolute, XenoCem, PermaCem, Fuji Cem and Fuji Plus were investigated with specimen sub-groups (N=10) for each property measured. The principal series of experiments was conducted in dentin cavities with interfacial polishing either immediately (3 min) after setting or after 24 h water-storage. After the finishing procedure, the maximum marginal gap width and the opposing width (if any) per cavity were measured microscopically, and summed. Then the overall sum of gap-widths (per group; N=10) was calculated. Marginal gaps were similarly measured in Teflon cavities, together with shear-bond-strengths to dentin and early flexural strengths, moduli and swelling data.
Results:
For specimen-sets polished immediately after setting, summed marginal gaps of 23-121 microm were observed, for all luting cements except Compolute. A significantly different (p<0.05) result of either no gap or 6-28 microm summed gap-widths occurred in specimens polished after 24 h. For all materials, their shear-bond-strengths, flexural strength and moduli significantly increased after 24 h storage.
Significance:
The marginal behavior can be interpreted in terms of the contributions of bonding, shrinkage, swelling and compliance of components, along with compositional features of the cements. With these types of cement it is generally inadvisable to polish the interfacial luting surface immediately after cementing. The polishing procedures should be carried out not less than 24 h later. One resin-cement was able to withstand immediate finishing.
Related Concept Videos
Types of Cement II
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Testing Water Quality
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
Soundness of Cement
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...