Dynamic Assessments of Coronary Flow Reserve after Myocardial Ischemia Reperfusion in Mice
Published on: August 25, 2023
Real-time myocardial contrast echocardiography for pharmacologic stress testing: is quantitative estimation of
Grigorios Korosoglou1, K Gaspar C da Silva, Nino Labadze
1Department of Cardiology, University of Heidelberg, Heidelberg, Germany.
Background:
Little is known about the diagnostic accuracy of quantitative real-time myocardial contrast echocardiography (MCE) as an adjunct to stress testing. This study was performed to evaluate the agreement between MCE and technetium 99m-sestamibi single photon emission computed tomography (SPECT) for detection of perfusion defects and to investigate whether quantitative assessment of myocardial perfusion can increase the diagnostic value of MCE.
Methods:
MCE was performed at rest and during peak adenosine stress in 50 unselected patients undergoing SPECT imaging. Concordance between the 2 methods was assessed using kappa statistics. MCE images were analyzed quantitatively, measuring peak intensity (A) and maximal rise of signal intensity (beta). Myocardial blood flow reserve was estimated by calculating the ratios of A(adenosine)/A(baseline) (A reserve), beta(adenosine)/beta(baseline) (beta reserve), and A x beta(adenosine)/A x beta(baseline) (A x beta reserve).
Results:
Visual analysis of MCE agreed well with SPECT (kappa = 0.67) with sensitivity of 64%, specificity of 97%, and overall accuracy of 87%. Quantitative analysis showed that peak signal intensity A significantly increased under adenosine stress in SPECT-normal segments (2.6 +/- 1.9 vs 3.0 +/- 1.6 dB, P <.0001), tendencially decreased in reversible (3.0 +/- 2.0 vs 2.4 +/- 1.2 dB, P =.07) and remained unchanged in fixed (0.9 +/- 0.9 vs 0.8 +/- 0.9 dB) defects. beta Increased markedly under adenosine in normal segments (0.4 +/- 0.4 vs 1.4 +/- 1.3, P <.0001) but not in segments with reversible or fixed defects. Receiver operating characteristic showed that beta reserve and A x beta reserve, but not A reserve, are sensitive parameters for detecting perfusion defects with areas under the curve of 0.84, 0.85, and 0.61, respectively. Cut-off values of 1.9 and 2.3, respectively, for beta and A x beta reserve yielded sensitivity rates of 79% and 80%, specificity rates of 75% and 78%, and overall accuracy rates of 76% and 79%, respectively.
Conclusion:
Quantitative estimation of myocardial blood flow reserve by MCE parameters corresponds to the evaluation of myocardial perfusion by nuclear imaging and can increase the sensitivity but not the overall accuracy of contrast echocardiography.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...