Related Experiment Video
Updated: Aug 29, 2026

Instrumentation of Near-term Fetal Sheep for Multivariate Chronic Non-anesthetized Recordings
Published on: October 25, 2015
Is amniotic fluid volume status predictive of fetal acidosis at delivery?
Everett F Magann1, Suneet P Chauhan, James N Martin
1Department of Obstetrics and Gynecology, The University of Western Australia, Perth, Australia. pmagann@obsgyn.uwa.edu.au
Objective:
To ascertain if dye-determined amniotic fluid volume just prior to delivery correlates with fetal acidosis at delivery.
Design:
The present was a prospective observational study.
Setting:
The study took place at the University of Mississippi Medical Center, Jackson MS, USA.
Population:
The population included 100 unlaboured women undergoing an amniocentesis for the assessment of fetal lung maturity before an elective Caesarean delivery between January 1997 and December 2000.
Main Outcomes Measured:
The amniotic fluid volume was estimated by ultrasound measurement and quantified by dye-determined methodology immediately prior to Caesarean delivery. Umbilical cord artery pH was collected at the time of Caesarean delivery.
Results:
The predictive accuracy of an amniotic fluid index < or = versus > 5 to identify an umbilical artery pH of < 7.20 had a sensitivity of 0%, a specificity of 84%, and a likelihood ratio of zero. None of the dye-determined low amniotic fluid volumes were identified using the single deepest pocket technique. Dye-determined low, normal, and high amniotic fluid volume groups contained a similar number of fetuses with umbilical cord arterial pH < 7.20 (P = 0.371), < 7.10 (P = 0.460), and < 7.00 (P = 0.614). Receiver-operating characteristic curves could not identify any amniotic fluid index from 0 to 18, single deepest pocket from 0 to 12, or dye-determined amniotic fluid volume 100-1900 mL to differentiate between the two newborns with an umbilical cord artery pH < 7 from 98 babies with cord pH > or = 7.0.
Conclusions:
Neither ultrasound estimates nor dye-determined amniotic fluid volumes are predictive of a low umbilical artery pH at delivery.
Related Concept Videos
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Disorders of Acid-Base Balance
Respiratory Acidosis and Alkalosis
Respiratory acidosis occurs due to an increase in the partial pressure of carbon dioxide PCO2 in the blood. It often arises from shallow breathing or impaired gas exchange caused by...
Acid-Base Balance
When the pH of arterial blood rises above 7.45, it results in a condition called alkalosis. Conversely, a drop below 7.35 leads to...
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Solution Composition During Acid/Base Titrations
The α0 and α1 values represent the...
Titration of a Weak Acid with a Weak Base
As a result, there is no simple...