The selectivity filter of the tandem pore potassium channel TASK-1 and its pH-sensitivity and ionic selectivity
K Yuill1, I Ashmole, P R Stanfield
1Molecular Physiology Group, Department of Biological Sciences, University of Warwick, Gibbet Hill Road, Coventry, CV4 7AL, UK.
Abstract:
We have studied pH sensitivity and ionic selectivity of the tandem pore K(+) channel TASK-1 heterologously expressed in Xenopus oocytes. We fit pH sensitivity assuming that only one of the two residues H98 need be protonated for channels to be shut. The effect of protons was weakly voltage dependent with a p K(a) of 6.02 at +40 mV. Replacement of His (H98D, H98N) reduced pH sensitivity but did not abolish it. Use of a concatameric channel permitted replacement of one His residue only; this concatamer was fully pH-sensitive. Increasing the number of His residues to 4 (mutant D204H) abolished pH sensitivity over the physiological range. The implication that D204 plays a role in pH-sensitivity was confirmed by the finding that pH sensitivity over the physiological range was also abolished in the mutant D204N. Ionic selectivity was also altered in D204H, D204N and H98D mutants. P(Rb)/ P(K) was increased from 0.80+/-0.04 (n=19) in wild type to 1.06+/-0.04 (n=19) in D204H. H98D, D204H and D204N were permeable to Na(+) with P(Na)/ P(K)=0.39+/-0.03 (n=14) in H98D, 0.64+/-0.04 (n=18) in D204H and 0.33+/-0.07 (n=3) in D204N. Thus, the arrangement of ring of residues HDHD appears to optimise both pH sensitivity and ionic selectivity.
Related Concept Videos
Primary Active Transport
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow specific...
Primary Active Transport
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Potentiometry: Membrane Electrodes
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to the...