Related Experiment Video
Updated: Aug 29, 2026

Laser Microdissection-Based Protocol for the LC-MS/MS Analysis of the Proteomic Profile of Neuromelanin Granules
Published on: December 16, 2021
Automated extraction and description of dark areas in surface microscopy melanocytic lesion images
Giovanni Pellacani1, Costantino Grana, Rita Cucchiara
1Department of Dermatology, University of Modena and Reggio Emila, Modena, Italy.
Background:
Identification of dark areas inside a melanocytic lesion (ML) is of great importance for melanoma diagnosis, both during clinical examination and employing programs for automated image analysis.
Objective:
The aim of our study was to compare two different methods for the automated identification and description of dark areas in epiluminescence microscopy images of MLs and to evaluate their diagnostic capability.
Methods:
Two methods for the automated extraction of 'absolute' (ADAs) and 'relative' dark areas (RDAs) and a set of parameters for their description were developed and tested on 339 images of MLs acquired by means of a polarized-light videomicroscope.
Results:
Significant differences in dark area distribution between melanomas and nevi were observed employing both methods, permitting a good discrimination of MLs (diagnostic accuracy = 74.6 and 71.2% for ADAs and RDAs, respectively).
Conclusions:
Both methods for the automated identification of dark areas are useful for melanoma diagnosis and can be implemented in programs for image analysis.