Related Experiment Video
Updated: Aug 29, 2026

Isolation and Preparation of Bacterial Cell Walls for Compositional Analysis by Ultra Performance Liquid Chromatography
Published on: January 15, 2014
Isolation of poly(propylene glycol)s from water for quantitative analysis by reversed-phase liquid chromatography
Joanna Rychłowska1, Agnieszka Zgoła, Tomasz Grześkowiak
1Institute of Chemistry, Poznań University of Technology, ul. Piotrowo 3, 60-965 Poznań, Poland.
Abstract:
Procedures for the isolation of poly(propylene glycol)s (PPGs) from a water matrix have been developed. Solid-phase extraction with an octadecylsilica cartridge and elution with methanol or with a graphitised carbon black cartridge and elution with a mixture of dichloromethane-methanol (4:1) or liquid-liquid extraction with chloroform were all suitable for model samples. However, only liquid-liquid extraction was suitable both for model and real environmental samples. Methods for reversed-phase liquid chromatographic determination of PPGs based on derivatisation and ultraviolet or fluorescence detection have been developed. Four derivatisation agents [3,5-dinitrobenzoyl chloride, phenyl isocyanate, 1-naphthoyl chloride and 1-naphthyl isocyanate (NIC)] were tested. Only NIC was found to give good reproducibility as well as a satisfactory detection limit. Finally, a method with liquid-liquid extraction with chloroform, derivatisation with NIC and liquid chromatographic separation with fluorescence detection was established. The developed method shows a highly correlated linearity of the analytical signals of particular homologues within a wide concentration range (approximately from 0.01 to 10 mg l(-1)). The precision of measurements is satisfactory for homologues having 5-9 oxypropylene subunits and becomes worse with an increase in the number of oxypropylene subunits. The limit of detection is 2 microg l(-1) for the majority of homologues. The method is suitable for the isolation and quantitative determination of PPGs in river water samples and as a tool for biodegradation testing.
More Related Videos
09:47Isolation and Compositional Analysis of Plant Cuticle Lipid Polyester Monomers
Published on: November 22, 2015
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...