Gas-phase reactions for selective detection of the explosives TNT and RDX

Eduardo C Meurer1, Hao Chen, Leah Riter

  • 1Institute of Chemistry, State University of Campinas, UNICAMP, SP, Brazil.

Chemical Communications (Cambridge, England)
|January 23, 2004
PubMed

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Carboxylic Acids to Methylesters: Alkylation using Diazomethane01:33

Carboxylic Acids to Methylesters: Alkylation using Diazomethane

Carboxylic acids react with diazomethane in an ether solvent via alkylation at the carboxylate oxygen atom to give methyl esters of the corresponding acid with excellent yields.
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
Diazonium Group Substitution: –OH and –H01:19

Diazonium Group Substitution: –OH and –H

Nitrous acid, a weak acid, is prepared in situ via the reaction of sodium nitrite with a strong acid under cold conditions. This nitrous acid prepared in situ reacts with primary arylamines to form arenediazonium salts. Such reactions are known as diazotization reactions. As shown in Figure 1, the formation of arenediazonium salts begins with the decomposition of nitrous acid in an acidic solution to give nitrosonium ions.