Related Experiment Video
Updated: Aug 29, 2026

Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
[Palmar plating with the locking compression plate for dorsally displaced fractures of the distal radius--first
M Schütz1, S Kolbeck, A Spranger
1Klinik für Unfall- und Wiederherstellungschirurgie, Charité Berlin.
Abstract:
Injuries and irritation of extensor tendons are common problems in the treatment of fractures of the distal radius when plating is used via a dorsal approach. By the development of locking compression plates the possibility of palmar plating for dorsally displaced fractures of the distal radius is available. In this study our first clinical experiences using the 3.5 mm radius locking compression plate (LCP) are reported. Between February 2002 and September 2002 24 patients with dorsally displaced fractures of the distal radius were treated using a palmar approach with the LCP and included in a prospective study. The mean age of the patients was 52 years (28-87 years). Six weeks and six months after surgery a clinical assessment was done, the range of motion of the injured wrist was measured, and an X-ray control of the injured joint was performed. The preliminary results demonstrate the option of early functional treatment using the locking compression plate. Most of the patients had a good to excellent range of motion of the injured wrist which resulted in an early return to former activity. There were few intra- and postoperative complications. No irritation of the median nerve, no infection was observed. In one case a screw which was placed intraarticularly was removed prematurely. The palmar locking compression plate has been proven as a safe and effective implant for the treatment of dorsally displaced fractures of the distal radius.
More Related Videos
11:21Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
Bones of the Upper Limb: Ulna
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...