Direct resistively heated column gas chromatography (Ultrafast module-GC) for high-speed analysis of essential oils
Carlo Bicchi1, Claudio Brunelli, Chiara Cordero
1Dipartimento di Scienza e Tecnologia del Farmaco, Università degli Studi di Torino, via P. Giuria 9, I-10125 Torino, Italy. carlo.bicchi@unito.it
Abstract:
This study applies Ultrafast module-GC (UFM-GC) with direct resistively heated columns to routine analysis of a group of essential oils of differing complexities (chamomile, peppermint, rosemary and sage). Essential oils were analysed by conventional GC with conventional inner diameter (i.d.) columns (0.25 mm) of different lengths (5 and 25 m long) and by Fast GC and Ultrafast module-GC with narrow bore columns (0.1 mm i.d., 5 m long). Column performance were evaluated and compared through their Grob test, separation number and peak capacity. Ultrafast module-GC was successful in the qualitative and quantitative analysis of essential oils of different compositions with analysis times between 40 s and 2 min versus 20-60 min required by conventional GC. Critical pairs or groups of components were separated by carefully tuning selectivity of the stationary phase to compensate for loss of efficiency due to the use of short columns and high temperature rates. The Ultrafast module-GC results of peppermint e.o. analyses were also validated and compared to those obtained by conventional GC; by measuring precision over time (i.e. repeatability and intermediate precision) and accuracy. Ultrafast module-GC showed a good separation reproducibility affording reliable component identification through the relative retention times and quantitative determination through normalised peak areas. Accuracy data also showed that Ultrafast module-GC and conventional GC normalised areas and areas percentage were perfectly comparable.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...