Related Experiment Video
Updated: Aug 29, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Evaluation of different liquid chromatography-electrospray mass spectrometry systems for the analysis of heterocyclic
E Barceló-Barrachina1, E Moyano, L Puignou
1Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, E-08028 Barcelona, Spain.
Abstract:
Three liquid chromatography-electrospray ionisation (LC-ESI) MS systems are evaluated for the analysis of heterocyclic amines (HAs). The electrospray sources and analysers (ion trap, single quadrupole and triple quadrupole) have been compared in terms of performance and quality parameters. In all cases, a C8 reversed-phase column and (acetic acid-ammonium acetate 30 mM pH 4.5)-acetonitrile (ACN) as mobile phase were used. Ionisation source parameters, post-column addition and working conditions for each acquisition mode (full scan, product ion scan, selected ion monitoring, and multiple reaction monitoring) were optimised for each instrument. The MS-MS spectra obtained with the ion trap and the triple quadrupole systems were very similar in both fragment ions and relative abundances, except for carbolines that showed adduct formation in the ion trap. Quality parameters were established and good precision (relative standard deviations (R.S.D.) < 12%) and very low limits of detection were obtained, mainly when using the triple quadrupole (< 9 pg injected). The content of HAs in a lyophilised beef extract was determined using the three instruments in order to compare their applicability for routine HAs analysis.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Mass Spectrometry of Amines
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing a single or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...