Related Experiment Video
Updated: Aug 29, 2026

Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
Ion chromatographic determination of sulfide and cyanide in real matrices by using pulsed amperometric detection on a
Caterina Giuriati1, Silvano Cavalli, Alfredo Gorni
1Ambiente s.p.a., Centro Igiene e Protezione Ambiente, Piazzale Donegani 12, 44100 Ferrara, Italy.
Abstract:
The determination of free sulfide and cyanide by pulsed amperometric detection (PAD) at a silver-working electrode was improved through a deep de-oxygenation (at least 10 min) of both standard and real solutions containing the two analytes and adopting a two-potential waveform able to eliminate Ag working electrode fouling. The waveform stepped around the oxidation of Ag in the presence of 0.1-0.4 M hydroxyl ion, from -0.1 to 0.1 V versus saturated calomel electrode (SCE). The eluent composition (0.4 M NaOH plus 7.5 mM oxalate solution) allowed a very good column efficiency and selectivity. The presence of a polysulfide species was hypothesized in sulfide solutions that had not been de-oxygenated and aged. The polysulfide eluted just before sulfide and was confirmed by a chemical test with SO3(2-) producing the elimination of the polysulfide peak. Detection limits, according to the Hubaux-Vos method, were 1.0 and 2.0 microg/l for S2- and CN , respectively. We demonstrated good performance of the optimized method by repeatedly injecting standard solutions and by analyzing different real matrices. The method exhibited very good accuracy and repeatability (10 microg/l and a 500 microl injection loop, had a repeatability better than 3% for sulfide and 100 microg/l had a repeatability better than 1% for cyanide). The two-potential waveform ensured long-term stability of the electrode surface that required no manual polishing procedure for at least 1 month (20 analysis per day).
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
07:23Fabrication of Thin Film Silver/Silver Chloride Electrodes with Finely Controlled Single Layer Silver Chloride
Published on: July 1, 2020
Related Concept Videos
Electrodeposition
Electrodeposition can...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Amperometry: Overview
High-Performance Liquid Chromatography: Types of Detectors
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...