Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
The effect of long-term storage on the microleakage of composite resin restorations: qualitative and quantitative
Fernanda Tranchesi Sadek1, Sandra Kiss Moura, Rafael Yagüe Ballester
1Department of Dental Materials, School of Dentistry, University of São Paulo, Brazil.
Abstract:
The aim of this study was to evaluate the influence of storage periods of 24 hours and 3 months on the microleakage of class II cavities. Two methods of assessing microleakage were also compared. Class II cavities were prepared in sound human molars. MO cavities were restored using ABF experimental (Kuraray Medical Inc.) + Z250 composite resin (3M ESPE), and DO cavities were restored using Single Bond (3M ESPE) + Z250. After different storage periods, specimens were thermocycled, immersed in a dye (0.5% methylene blue solution for 4 h) and longitudinally sectioned. Dye penetration was scored according to a 0-4 scale. The extent of microleakage was measured using the ImageLab 2000 program. A statistically significant correlation was verified between both evaluation methods (r = 0.978, p < 0.001). ANOVA revealed a statistically significant difference between the tested adhesive systems regarding microleakage (p < 0.001), although it was not influenced by the different storage periods.