In Silico Analysis of Stress Distribution in Proximal Interphalangeal Joint Arthrodesis in Horses Using a Locking
Anderson Fernando de Souza1, César Augusto Martins Pereira2, Ivan Onone Gialain3
1Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo, São Paulo, Brazil.
None:
This study aimed to compare the stress distribution in proximal interphalangeal joint arthrodesis with locking compression plate in horses based on the type and method of screw implantation in the proximal hole and partial or total removal of implants after fusion.Finite element analysis.Proximal interphalangeal joint arthrodesis was simulated using a 3-hole, 4.5-mm narrow locking compression plate combined with two 5.5-mm transarticular screws. Models were created according to the type (cortex or locking) and method of implantation (uni- or bicortical) of the screw in the proximal hole of the locking compression plate. Four conditions were simulated: Immediate postoperative, ankylosis, ankylosis with partial removal (transarticular screws remaining) and ankylosis with no implants. An axial load of 8,700 N was applied, and the major principal stresses in the bones and von Mises stress in the implants were evaluated.Cortical screws in the proximal hole better distributed the stresses, reducing their concentration along the diaphysis of the proximal phalanx in the postoperative condition. Stress distribution did not differ between partial and total implant removal. High stresses were observed in the implants, especially when locking screws were used, with a reduction observed after ankylosis simulation.A cortex screw in the proximal hole reduces stress concentration in the proximal phalanx. Retaining the transarticular screws after ankylosis did not alter the stress pattern in the bone.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
05:34A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
Related Concept Videos
Frames: Problem Solving I
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Collar Bearings
Fluid Pressure over Flat Plate of Constant Width
The resultant force...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Applications of Stress
The...