A new oxygenation index for reflecting intrapulmonary shunting in patients undergoing open-heart surgery
Mohamad F El-Khatib1, Ghassan W Jamaleddine
1Department of Anesthesiology, School of Medicine, American University of Beirut, PO Box 11-0236, Riad El Solh, Beirut 1107 2020, Lebanon. mk05@aub.edu.lb
Study Objectives:
To assess the reliability of new and traditional oxygenation measurements in reflecting intrapulmonary shunt.
Design:
Prospective study.
Setting:
Cardiac surgery unit at a university hospital.
Patients:
Fifty-five patients undergoing coronary artery bypass grafting.
Measurements And Results:
Simultaneous blood samples were collected from an indwelling arterial line and a catheter for determination of blood gases. Standard accepted formulas were utilized to measure a new oxygenation index: PaO(2)/fraction of inspired oxygen (FIO(2)) x mean airway pressure (Paw). The standard formulas used were the oxygenation ratio (PaO(2)/FIO(2)), PaO(2)/alveolar partial oxygen pressure (PAO(2)), alveolar-arterial oxygen tension gradient (P[A-a]O(2)), and intrapulmonary shunt (venous admixture [Qsp/Qt]). There were significant negative (p < 0.05) correlations between the PaO(2)/(FIO(2) x Paw) and Qsp/Qt (r = - 0.85), between the PaO(2)/FIO(2) and Qsp/Qt (r = - 0.74), and between the PaO(2)/PAO(2) and Qsp/Qt (r = - 0.71). There was a significant positive (p < 0.05) correlation between the P(A-a)O(2) gradient and Qsp/Qt (r = 0.66). However, the correlation was strongest between the PaO(2)/(FIO(2) x Paw) and Qsp/Qt.
Conclusion:
In this group of patients, PaO(2)/(FIO(2) x Paw) might be more reliable than other oxygenation measurements in reflecting intrapulmonary shunt.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.