Background:
Traditional catheter-based oesophageal pH testing is limited by patient discomfort and the tendency for patients to alter their diet and activities during the study. A catheter-free pH monitoring system (Bravo) designed to avoid these problems has recently become available, but the advantages and limitations of this device have not been fully explored.
Aim:
To report our initial experience with this new technology.
Methods:
The records of consecutive patients undergoing Bravo pH monitoring were reviewed. The squamo-columnar junction was localized endoscopically and the pH capsule was placed 6 cm above this junction. All patients were re-endoscoped immediately following placement to document mucosal attachment. Patients were monitored for 24-48 h and then returned the radiotelemetry recording device. Data were subsequently downloaded to a personal computer.
Results:
Sixty studies were performed over an 11-month period. In seven of the 60 (12%), the probe did not attach properly, but in six of these a replacement probe was prepared and deployed without difficulty. In one case, the probe could not be attached after two attempts and the procedure was abandoned. During one procedure, the probe was attached to the mucosa at a point 9 cm from the squamo-columnar junction, but a positive test result was obtained. In two cases, the data were not initially retrievable from the recorder, but in one case the manufacturer was able to retrieve the data overnight. Finally, two patients were away from the data recorder for extended periods, resulting in a loss of data, in two cases, but there was sufficient information for interpretation in both studies. Therefore, adequate diagnostic data were obtained in 58 of the 60 (97%) studies.
Conclusions:
Catheter-free pH testing is a major advance in patient convenience and comfort. The technical difficulties associated with this new technology are minimal and appear to be no more frequent than those seen with catheter-based systems.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Holter Monitor: 24-Hour Monitoring