Related Experiment Video
Updated: Aug 18, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Gadolinium magnetic resonance contrast agents produce analytic interference in multiple serum assays
Kerry A S Proctor1, Lokinendi V Rao, William L Roberts
1Department of Pathology, University of Utah Health Sciences Center, Salt Lake City, USA.
Abstract:
Gadolinium magnetic resonance contrast agents are known to interfere with some clinical chemistry tests, particularly colorimetric assays for serum calcium. We studied the effects of 4 agents, gadodiamide, gadoversetamide, gadopentetate dimeglumine, and gadoteridol, for interference with multiple serum assays. Gadodiamide and gadoversetamide produced clinically significant negative interference with colorimetric assays for serum angiotensin-converting enzyme, calcium, and zinc. These agents produced clinically significant positive interference in magnesium and total iron binding capacity assays and both positive and negative interference in iron assays. Gadopentetate dimeglumine produced a negative interference with iron assays, and gadopentetate dimeglumine and gadoteridol produced negative interference with a colorimetric zinc assay. Caution should be exercised when using colorimetric assays for angiotensin-converting enzyme, calcium, iron, magnesium, total iron binding capacity, and zinc in serum samples from patients who have recently received magnetic resonance contrast agents. In general, gadodiamide and gadoversetamide are more likely to produce a clinically significant interference than gadopentetate dimeglumine and gadoteridol. Likewise, certain analytic methods are more prone to interference, while others not affected.
Related Concept Videos
Magnetic Resonance Imaging
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging